Heat treatment
For the first class cold heading property of our wires, the type of annealing treatment is of major importance. In addition to a double-vacuum hood-type annealing furnace which can be operated with nitrogen, a state of the art oxygen-operated hood-type annealing furnace, brand Ebner HICON / H2, was purchased in 1999. The temperature/time runs are continuously measured, controlled and documented during the annealing process.

Types:

Heat-treated wire rods
+ U + C = K - cold drawn
+ U + C + AC = KG - cold drawn, finally annealed
+ AC + C = GK - annealed, cold drawn
+ U + C + AL +  LC = KGK - cold drawn, annealed, finally drawn
Photo 1  Photo 2